Search results for "cardiac cycle"
showing 10 items of 27 documents
Realignment of myocardial first-pass MR perfusion images using an automatic detection of the heart-lung interface
2004
International audience; Abstract: Magnetic resonance first-pass imaging of a bolus of contrast agent is well adapted to distinguish normal and hypoperfused areas of the myocardium. In most cases, the signal intensity-time curves in user defined regions of interest (ROI) are studied. As image acquisition is ECG-gated, the images are acquired at the same moment in the cardiac cycle, and the basic shape of the heart is similar from one view to the next. However, superficial respiratory motion can displace the heart in the short-axis plane. The aim of this study is to correct for the respiratory motion of the heart by performing an automatic realignment of the myocardial ROI based on a method t…
Learning by heart : cardiac cycle reveals an effective time window for learning
2018
Cardiac cycle phase is known to modulate processing of simple sensory information. This effect of the heartbeat on brain function is likely exerted via baroreceptors, the neurons sensitive for changes in blood pressure. From baroreceptors, the signal is conveyed all the way to the forebrain and the medial prefrontal cortex. In the two experiments reported, we examined whether learning, as a more complex form of cognition, can be modulated by the cardiac cycle phase. Human participants ( experiment 1) and rabbits ( experiment 2) were trained in trace eyeblink conditioning while neural activity was recorded. The conditioned stimulus was presented contingently with either the systolic or dias…
Timing of Triggering in Relation to the Cardiac Cycle in Nonelite Rifle Shooters
2003
This study investigated the timing of the trigger pull in relation to the cardiac cycle during air rifle shooting. Electrocardiogram) was recorded from 20 male nonelite rifle shooters in two separate testing sessions. The testing was conducted at an indoor shooting range using an optoelectronic shooting system. Each participant fired a shot in the standing position at a distance of 10 m from the target. The results showed that compared to random triggering, the shooters fired more often during the phase of 10-50% of the R wave-to-R wave (R-R) interval and less often during the phase of 50-90%. With regard to performance accuracy, the participants exhibited average or above average performan…
Cardiac modulation of startle is altered in depersonalization-/derealization disorder: Evidence for impaired brainstem representation of baro-afferen…
2016
Patients with depersonalization-/derealization disorder (DPD) show altered heartbeat-evoked brain potentials, which are considered psychophysiological indicators of cortical representation of visceral-afferent neural signals. The aim of the current investigation was to clarify whether the impaired CNS representation of visceral-afferent neural signals in DPD is restricted to the cortical level or is also present in sub-cortical structures. We used cardiac modulation of startle (CMS) to assess baro-afferent signal transmission at brainstem level in 22 DPD and 23 healthy control individuals. The CMS paradigm involved acoustic startle stimuli (105dB(A), 50ms) elicited 0, 100, 200, 300, 400 and…
Perceptual Performance as a Function of Intra-Cycle Cardiac Activity
1975
The purpose of the experiment was to test the hypothesis of a systematic change in perceptual performance within a single cardiac cycle due to the activity of the baroreceptors in carotid sinus. As an index of perceptual performance the ds-parameter from signal detection theory (TSD) was used. A 1000 Hz sine tone had to be detected in a background of white noise. Each of 4 subjects received on the average 4605 noise or noise plus tone stimuli distributed over 10 experimental sessions. When comparing performance during time intervals before and after baroreceptor activity onset no significant difference was found. Also, when tracing perceptual performance over the whole cardiac cycle in step…
Left ventricular ejection fraction calculation from automatically selected and processed diastolic and systolic frames in short-axis cine-MRI
2005
International audience; Abstract: The calculation of the left ventricular ejection fraction (LVEF) is dependent upon the accurate measurement of diastolic and systolic left ventricular volumes. Although breath-hold cine magnetic resonance imaging (MRI) allows coverage of the whole cardiac cycle with an excellent time resolution, many authors rely on the visual selection of diastolic and the systolic short-axis slices in order to reduce the postprocessing time. An automatic method was developed to detect the endocardial contour on each image, allowing an automatic selection of the systolic frame. The calculated ejection fraction was compared with radionuclide ventriculography (RNV). Sixty-fi…
Storage and release of false transmitters after infusion of (+)- and (?)-?-methyldopamine
1971
Rabbits were given an infusion of 10 mg/kg (−)- or 30 mg/kg (+)-α-methyldopamine and killed after 135 min. The noradrenaline content of the heart was decreased to 26±5 and 34±2%, respectively, of the control value. After infusion of the (+)-isomer the missing noradrenaline was replaced by (−)-α-methylnoradrenaline. Electrical stimulation of the sympathetic nerves or infusion of acetylcholine plus atropine caused an output of noradrenaline and (−)-α-methylnoradrenaline from the isolated heart. The two amines were released in the same proportion as they were stored in the heart and the total output of both amines equalled the output of noradrenaline from control hearts. Nerve stimulation caus…
<title>A portable device for optical assessment of the cardiovascular condition</title>
2003
A hand-held prototype device for detection and processing of the tissue-remitted optical signals has been developed and tested. The photoplethysmography (PPG) principle was applied to follow the dilation and contraction of skin blood vessels during the cardiac cycle. Cardiovascular condition of the monitored person was assessed by temporal analysis of the recorded PPG signals as well as by shape analysis of the mean single-period PPG signals.© (2003) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
The automated assesment of artery hemodynamic parameters from ultrasound video
2012
The custom designed video processing software for analysis of B-mode and Doppler-mode ultrasound video has been proposed in this work. The software allows adjusting user-defined thresholds and tolerance levels to enhance contour detection in noisy and artifacted ultrasound images. The developed software is able to evaluate 16 hemodynamic parameters (artery diameter, pulse rate and flow velocity related parameters) in each cardiac cycle. The measurements were performed intermittently recording artery diameter (B-mode) and flow velocity (Doppler-mode). Software has validated in femoral artery measurements. The hemodynamic parameters computed by software were consistent with those obtained by …
Improving diagnostic accuracy of MDCT coronary angiography in patients with mild heart rhythm irregularities using ECG editing
2006
OBJECTIVE. The objective of our study was to compare diagnostic accuracy of MDCT coronary angiography in a population of patients with mild heart rhythm irregularities before and after editing the ECG. SUBJECTS AND METHODS. Thirty-eight patients who underwent MDCT coronary angiography and conventional coronary angiography were enrolled in the study. The inclusion criterion was the presence of mild heart rhythm irregularities (i.e., premature beats; atrial fibrillation; mistriggering; or low heart rate, defined as 40 beats per minute or less) during the scan. All patients underwent MDCT with the following parameters: 16 detectors; collimation, 0.75 mm; gantry rotation time, 375 msec; 120 kV;…